‏786.00 ₪

Instantaneous Power Theory and Applications to Power Conditioning 2e

‏786.00 ₪
ISBN13
9781118362105
יצא לאור ב
New York
מהדורה
2nd Edition
זמן אספקה
21 ימי עסקים
עמודים
472
פורמט
Hardback
תאריך יציאה לאור
21 באפר׳ 2017
מחליף את פריט
14510761000
שם סדרה
IEEE Press Series on Power Engineering
Suitable for students and a solid reference for professionals, this book presents a review of power theories and shows that the instantaneous power theory gives important basic knowledge for the understanding and designing of shunt, series, combined shunt-series power active filters as well as hybrid passive-active power filters.
This book covers instantaneous power theory as well as the importance of design of shunt, series, and combined shunt-series power active filters and hybrid passive-active power filters * Illustrates pioneering applications of the p-q theory to power conditioning, which highlights distinct differences from conventional theories * Explores p-q-r theory to give a new method of analyzing the different powers in a three-phase circuit * Provides exercises at the end of many chapters that are unique to the second edition
מידע נוסף
מהדורה 2nd Edition
עמודים 472
מחליף את פריט 14510761000
פורמט Hardback
ISBN10 1118362101
יצא לאור ב New York
תאריך יציאה לאור 21 באפר׳ 2017
תוכן עניינים PREFACE xiii CHAPTER 1 INTRODUCTION 1 1.1 Concepts and Evolution of Electric Power Theory 1 1.2 Applications of the P-q Theory to Power Electronics Equipment 4 1.3 Harmonic Voltages in Power Systems 5 1.4 Identified and Unidentified Harmonic-Producing Loads 6 1.5 Harmonic Current and Voltage Sources 8 1.6 Basic Principles of Harmonic Compensation 9 1.7 Basic Principle of Power Flow Control 13 References 15 CHAPTER 2 ELECTRIC POWER DEFINITIONS: BACKGROUND 17 2.1 Power Definitions Under Sinusoidal Conditions 18 2.2 Voltage and Current Phasors and Complex Impedance 20 2.3 Complex Power and Power Factor 21 2.4 Concepts of Power Under Nonsinusoidal Conditions: Conventional Approaches 22 2.4.1 Power Definitions by Budeanu 22 2.4.1.A Power Tetrahedron and Distortion Factor 25 2.4.2 Power Definitions by Fryze 27 2.5 Electric Power in Three-Phase Systems 28 2.5.1 Classifications of Three-Phase Systems 28 2.5.2 Power in Balanced Three-Phase Systems 31 2.5.3 Power in Three-Phase Unbalanced Systems 33 2.6 Summary 34 2.7 Exercises 34 References 35 CHAPTER 3 THE INSTANTANEOUS POWER THEORY 37 3.1 Basis of the p-q Theory 37 3.1.1 Historical Background of the p-q Theory 38 3.1.2 The Clarke Transformation 39 3.1.2.A Calculation of Voltage and Current Vectors When Zero-Sequence Components Are Excluded 41 3.1.3 Three-Phase Instantaneous Active Power in Terms of Clarke Components 43 3.1.4 The Instantaneous Powers of the p-q Theory 44 3.2 The p-q Theory in Three-Phase, Three-Wire Systems 44 3.2.1 Comparisons with the Conventional Theory 48 3.2.1.A Example #1 Sinusoidal Voltages and Currents 49 3.2.1.B Example #2 Balanced Voltages and Capacitive Loads 49 3.2.1.C Example #3 Sinusoidal Balanced Voltage and Nonlinear Load 50 3.2.2 Use of the p-q Theory for Shunt Current Compensation 54 3.2.2.A Examples of Appearance of Hidden Currents 59 3.2.3 The Dual p-q Theory 63 3.3 The p-q Theory in Three-Phase, Four-Wire Systems 65 3.3.1 The Zero-Sequence Power in a Three-Phase Sinusoidal Voltage Source 67 3.3.2 Presence of Negative-Sequence Components 68 3.3.3 General Case Including Distortions and Imbalances in the Voltages and in the Currents 69 3.3.4 Physical Meanings of the Instantaneous Real, Imaginary, and Zero-Sequence Powers 74 3.3.5 Avoiding the Clarke Transformation in the p-q Theory 75 3.3.6 Modified p-q Theory 77 3.4 Instantaneous abc Theory 81 3.4.1 Active and Nonactive Current Calculation by Means of a Minimization Method 83 3.4.2 Generalized Fryze Currents Minimization Method 88 3.5 Comparisons Between the p-q Theory and the abc Theory 91 3.5.1 Selection of Power Components to be Compensated 95 3.6 The p-q-r Theory 97 3.7 Summary 104 3.8 Exercises 105 References 106 CHAPTER 4 SHUNT ACTIVE FILTERS 111 4.1 General Description of Shunt Active Filters 113 4.1.1 PWM Converters for Shunt Active Filters 114 4.1.2 Active Filter Controllers 115 4.2 Three-Phase, Three-Wire Shunt Active Filters 118 4.2.1 Active Filters for Constant Power Compensation 119 4.2.2 Active Filters for Sinusoidal Current Control 135 4.2.2.A Positive-Sequence Voltage Detector 138 4.2.2.B Simulation Results 145 4.2.3 Active Filters for Current Minimization 145 4.2.4 Active Filters for Harmonic Damping 149 4.2.4.A Shunt Active Filter Based on Voltage Detection 151 4.2.4.B Active Filter Controller Based on Voltage Detection 152 4.2.4.C An Application Case of an Active Filter for Harmonic Damping 156 4.2.5 A Digital Controller 171 4.2.5.A System Configuration of the Digital Controller 172 4.2.5.B Current Control Methods 177 4.3 Three-Phase, Four-Wire Shunt Active Filters 180 4.3.1 Converter Topologies for Three-Phase, Four-Wire Systems 181 4.3.2 Dynamic Hysteresis-Band Current Controller 182 4.3.3 Active Filter dc Voltage Regulator 184 4.3.4 Optimal Power Flow Conditions 185 4.3.5 Constant Instantaneous Power Control Strategy 187 4.3.6 Sinusoidal Current Control Strategy 189 4.3.7 Performance Analysis and Parameter Optimization 192 4.3.7.A Influence of the System Parameters 192 4.3.7.B Dynamic Response of the Shunt Active Filter 193 4.3.7.C Economical Aspects 198 4.3.7.D Experimental Results 199 4.4 Compensation Methods Based on the p-q-r Theory 204 4.4.1 Reference Power Control Method 206 4.4.2 Reference Current Control Method 211 4.4.3 Alternative Control Method 213 4.4.4 The Simplified Sinusoidal Source Current Strategy 215 4.4.4.A The PLL Circuit and the Positive-Sequence Detector 215 4.4.4.B The Sinusoidal Source Current Control Strategy with Energy Balance Inside the Active Filter 217 4.5 Comparisons Between Control Methods Based on the p-q Theory and the p-q-r Theory 218 4.6 Shunt Selective Harmonic Compensation 224 4.7 Summary 231 4.8 Exercises 231 References 233 CHAPTER 5 HYBRID AND SERIES ACTIVE FILTERS 237 5.1 Basic Series Active Filter 237 5.2 Combined Series Active Filter and Shunt Passive Filter 239 5.2.1 Example of an Experimental System 242 5.2.1.A Compensation Principle 243 5.2.1.B Filtering Characteristics 245 5.2.1.C Control Circuit 246 5.2.1.D Filter to Suppress Switching Ripples 248 5.2.1.E Experimental Results 249 5.2.2 Some Remarks about the Hybrid Filters 252 5.3 Series Active Filter Integrated with a Double-Series Diode Rectifier 253 5.3.1 The First-Generation Control Circuit 255 5.3.1.A Circuit Configuration and Delay Time 255 5.3.1.B Stability of the Active Filter 257 5.3.2 The Second-Generation Control Circuit 258 5.3.3 Stability Analysis and Characteristics Comparison 260 5.3.3.A Transfer Function of the Control Circuits 260 5.3.3.B Characteristics Comparisons 261 5.3.4 Design of a Switching-Ripple Filter 263 5.3.4.A Design Principle 263 5.3.4.B Effect on the System Stability 263 5.3.4.C Experimental Testing 264 5.3.5 Experimental Results 266 5.4 Comparisons Between Hybrid and Pure Active Filters 268 5.4.1 Low-Voltage Transformerless Hybrid Active Filter 268 5.4.2 Low-Voltage, Transformerless, Pure Shunt Active Filter 271 5.4.3 Comparisons through Simulation Results 273 5.5 Hybrid Active Filters for Medium-Voltage Motor Drives 274 5.5.1 Hybrid Active Filter for a Three-Phase Six-Pulse Diode Rectifier 275 5.5.1.A System Configuration 275 5.5.1.B Experimental System 277 5.5.1.C Control System 277 5.5.1.D Common Sixth-Harmonic Zero-Sequence Voltage Injection 281 5.5.1.E Three-Phase Second-Harmonic Negative Sequence Voltages Injection 283 5.5.1.F Experimental Results 286 5.5.1.G Appendix 292 5.5.2 Hybrid Active Filter for a Three-Phase 12-Pulse Diode Rectifier 292 5.5.2.A Medium-Voltage High-Power Motor Drive Systems 293 5.5.2.B Experimental System 295 5.5.2.C Control System 298 5.5.2.D Three-Phase Second-Harmonic Negative Sequence Voltages Injection 300 5.5.2.E Experimental Results 303 5.5.2.F Overall System Efficiency 308 5.6 Summary 308 5.7 Exercises 309 References 310 CHAPTER 6 COMBINED SERIES AND SHUNT POWER CONDITIONERS 313 6.1 The Unified Power Flow Controller 314 6.1.1 FACTS and UPFC Principles 315 6.1.1.A Voltage Regulation Principle 317 6.1.1.B Power Flow Control Principle 318 6.1.2 A Controller Design for the UPFC 321 6.1.3 UPFC Approach Using a Shunt Multipulse Converter 328 6.1.3.A Six-Pulse Converter 328 6.1.3.B Quasi 24-Pulse Converter 332 6.1.3.C Control of Active and Reactive Power in Multipulse Converters 334 6.1.3.D Shunt Multipulse Converter Controller 336 6.2 The Unified Power Quality Conditioner 339 6.2.1 General Description of the UPQC 340 6.2.2 A Three-Phase, Four-Wire UPQC 342 6.2.2.A Power Circuit of the UPQC 343 6.2.2.B The UPQC Controller 344 6.2.2.C Analysis of the UPQC Dynamic 353 6.2.3 The UPQC Combined with Passive Filters (the Hybrid UPQC) 370 6.2.3.A Controller of the Hybrid UPQC 374 6.2.3.B Experimental Results 380 6.3 The Universal Active Power Line Conditioner 386 6.3.1 General Description of the UPLC 386 6.3.2 The Controller of the UPLC 389 6.3.2.A Controller for Configuration #2 of the UPLC 396 6.3.3 Performance of the UPLC 397 6.3.3.A Normalized System Parameters 397 6.3.3.B Simulation Results of Configuration #1 of the UPLC 401 6.3.3.C Simulation Results of Configuration #2 of the UPLC 409 6.3.4 General Aspects 411 6.4 Combined Shunt-Series Filters for AC and DC Sides of Three-Phase Rectifiers 411 6.4.1 The Combined Shunt-Series Filter 414 6.4.2 Instantaneous Real and Imaginary Powers in the ac Source 415 6.4.3 The Instantaneous Power in the dc Side of the Rectifier 416 6.4.4 Comparison of Instantaneous Powers on the ac and dc Sides of the Rectifier 418 6.4.5 Control Algorithm of the Active Shunt-Series Filter 418 6.4.6 The Common dc Link 421 6.4.7 Digital Simulation 424 6.4.8 Experimental Results 426 6.5 Summary 427 6.6 Exercises 428 References 429 INDEX 431
זמן אספקה 21 ימי עסקים